How accurate is an ultrasound in determining age of fetus

In the past gestational age was established by a combination of the historical information and the physical examination. Reliance was placed on the menstrual history and the maternal sensation of fetal movement (“quickening”). Other factors include assessment of uterine size by bimanual examination in the first trimester, initial detection of fetal heart tones by Doppler (10–12 weeks) or auscultation (19–21 weeks), and uterine fundal height measurement. However, both the history and the findings on physical examination are fraught with error, even in the best of circumstances (Table 1).6,7,8 It has been estimated that 20% to 40% of women cannot relate the LMP with certainty.6,7 Some of the reasons for this uncertainty include oligomenorrhea, metrorrhagia, bleeding in the first trimester of pregnancy, pregnancy following use of oral contraceptives or intrauterine devices, and becoming pregnant in the postpartum period. Hertz and co-workers9 reported that menstrual history was considered reliable in only 18% of women. In another report, even among women with known LMP, neonatal age assessment differed markedly from that assigned by certain menstrual dates in 15%.8 Physical examination also tends to be inaccurate, especially with advancing gestational age.10 Bimanual examination in the first trimester may be accurate within ±2 weeks; however, fundal height measurement, which is more commonly used to assess gestational age, is only accurate within ±4 to 6 weeks. Clearly, the inaccuracies of history and physical examination may limit their usefulness in assessment of gestational age. Methods that assess the time of ovulation or conception can accurately establish gestational age.11,12,13,14 Timed ovulation, either by basal body temperature recording or semiquantitative assessment of luteinizing hormone surge, predicts gestational age within ±4 to 6 days. Ovulation induction with agents such as clomiphene citrate and Pergonal, also accurately predicts gestational age. In vitro fertilization, with known date of conception, is likely the most accurate means of predicting gestational age (±1 day). However, in most pregnancies, the date of ovulation or conception cannot be as accurately predicted as outlined above and gestational age must be established by other methods.

TABLE 1.Clinical Predictors of Gestational Age

Estimated Range for

Parameter

95% of Cases

In vitro fertilization

±1 day

Ovulation induction

±4–6 days

Luteinizing hormone surge indicator

±4–6 days

Basal body temperature

±4–6 days

Certain menstrual history

±2 weeks

Bimanual examination (first trimester)

±2 weeks

First fetal heart tones by Doppler

±2 weeks

“Quickening”

±2–4 weeks

First fetal heart tones by auscultation

±2–4 weeks

Fundal height measurement between

±4 weeks

 18 and 32 weeks' gestation

Fundal height measurement after 32

±4–6 weeks

 weeks' gestation

The advent of ultrasound has allowed a more direct means of assessing fetal structures and development. Measurements of a wide variety of parameters have been devised to establish gestational age. Ultrasound assessment of gestational age is feasible in a majority of pregnancies and may be used to establish gestational age with greater accuracy than physical examination. In the first trimester, gestational sac mean diameter and crown-rump length measurements have become the primary means of evaluating gestational age.15,16,17,18,19 In the second and third trimesters, fetal head, body, and extremity measurements have been commonly used to assess gestational age. Those parameters most commonly measured include biparietal diameter,20,21,22,23,24,25,26,27,28 head circumference,29,30 abdominal circumference,31,32,33,34,35 and femur length.36,37,38,39 Although numerous other parameters have been measured and related to gestational age, few offer any improvement in the accuracy of gestational age assessment.40,41,42,43,44,45,46 In this chapter, the most widely used and accepted ultrasound-derived fetal growth parameters are discussed and a review of their accuracies and potential errors is presented.

First-Trimester Assessment

In the first trimester, the gestational sac mean diameter and crown-rump length are used to establish fetal age. Both parameters are useful because each measures a different aspect of the first-trimester pregnancy and may be used at different times during the first trimester.

GESTATIONAL SAC MEAN DIAMETER.

The gestational sac is the first identifiable structure routinely imaged in the first trimester. It is identified by transabdominal ultrasound as early as 5 weeks' gestation and may be seen as early as 4 weeks' gestation by transvaginal ultrasound.15,16,47 The gestational sac is an echo-free space containing the fluid, embryo, and extraembryonic structures. The sac is measured inside the hyperechoic rim, including only the echo-free space (Fig. 1). The gestational sac is imaged first in the longitudinal plane, obtaining long axis and anteroposterior measurements perpendicular to each other. Then, in the transverse plane at the level of the anteroposterior measurement, the width measurement is obtained. The three measurements are averaged to obtain the gestational sac mean diameter. Table 2 compares gestational ages from 5 to 12 weeks with the gestational sac mean diameters.15 The accuracy of gestational sac measurement as a predictor of gestational age has been evaluated in only one report and was found to be approximately ±1 week.16

TABLE 2. Gestational Sac Mean Diameter Measurements Relative to Gestational Age

Gestational Sac

Gestational Age

Gestational Sac

Gestational Age

Mean Diameter (mm)

(weeks)

Mean Diameter (mm)

(weeks)

10

5.0

30

7.9

11

5.2

31

8.0

12

5.3

32

8.2

13

5.5

33

8.3

14

5.6

34

8.5

15

5.8

35

8.6

16

5.9

36

8.8

17

6.0

37

8.9

18

6.2

38

9.0

19

6.3

39

9.2

20

6.5

40

9.3

21

6.6

41

9.5

22

6.8

42

9.6

23

6.9

43

9.8

24

7.0

44

9.9

25

7.2

45

10.0

26

7.3

46

10.2

27

7.5

47

10.3

28

7.6

48

10.5

29

7.8

49

10.6

(Hellman LF, Kobayashi M, Fillisti L et al: Growth and development of the human fetus prior to the twentieth week of gestation. Am J Obstet Gynecol 103:789, 1969. Reprinted with permission of CV Mosby, St. Louis.)

Fig. 1. A. Longitudinal image of a gestational sac. The longitudinal diameter is measured between the small crosses (1) and the anteroposterior diameter is measured between the larger crosses (2). B. Transverse image obtained at the level of the anteroposterior diameter. The transverse diameter is measured between the crosses.

CROWN-RUMP LENGTH.

The crown-rump length (CRL) is a measurement of the embryo, usually identified at 6 to 7 weeks' gestation.17,48 The embryo is measured along its longest axis to obtain the CRL measurement (Fig. 2). Crown-rump length may be used to accurately date pregnancy between 7 and 13 weeks' gestation. The technique involves measurement of the fetal length from the tip of the cephalic pole to the tip of the caudal pole. The fetus should be at rest and assuming its natural curvature. At 5 to 6 weeks' gestation, distinct landmarks cannot always be identified but heart motion usually can be detected centrally. As the pregnancy continues, the head can be easily identified from the rest of the body. After 12 weeks' gestation excessive curvature of the fetus may lead to erroneous shortening of CRL measurement; therefore, other measurements, such as the biparietal diameter, should be used to estimate gestational age.

Fig. 2. Ultrasound image of a fetus at 10 weeks' gestation. The crown-rump length is measured along the longest axis of the fetus ( between the arrows)

The correlation between sonographic CRL values and dates was first reported by Robinson and Fleming, who obtained CRLs in pregnancies of women with certain menstrual histories.17 Drumm and associates18 performed a similar study; however, their patients fulfilled more stringent dating criteria. These early studies suggested that gestational age assessment by CRL was extremely accurate, approaching ±3 to 4 days. Subsequent studies have suggested that the CRL is somewhat less accurate; however, the accuracy is still within ±5 to 7 days.49,50,51,52 Most recently, MacGregor and co-workers19 evaluated CRL measurements in pregnancies of women with known dates of ovulation and reported data that differed from those of the previous two studies. Table 3 summarizes the results of these three studies evaluating gestational age relative to CRL.

TABLE 3.Crown-Rump Length Measurements Relative to Gestational Age in Three Studies

MacGregor et

Robinson and

Drumm et

Crown-Rump

alGestational Age

FlemingGestational Age

alGestational Age

Length(cm)

(Weeks + Days)

(Weeks + Days)

(Weeks + Days)

1.0

7 + 5

7 + 0

6 + 6

1.1

7 + 6

7 + 1

7 + 1

1.2

8 + 0

7 + 3

7 + 2

1.3

8 + 1

7 + 4

7 + 3

1.4

8 + 1

7 + 5

7 + 4

1.5

8 + 2

7 + 6

7 + 5

1.6

8 + 3

8 + 0

7 + 6

1.7

8 + 4

8 + 1

8 + 0

1.8

8 + 5

8 + 2

8 + 1

1.9

8 + 5

8 + 3

8 + 2

2.0

8 + 6

8 + 4

8 + 3

2.1

9 + 0

8 + 5

8 + 4

2.2

9 + 1

8 + 6

8 + 5

2.3

9 + 1

8 + 6

8 + 6

2.4

9 + 2

9 + 0

9 + 0

2.5

9 + 3

9 + 1

9 + 1

2.6

9 + 4

9 + 2

9 + 2

2.7

9 + 4

9 + 3

9 + 3

2.8

9 + 5

9 + 3

9 + 3

2.9

9 + 6

9 + 4

9 + 4

3.0

9 + 6

9 + 5

9 + 5

3.1

10 + 0

9 + 6

9 + 6

3.2

10 + 1

9 + 6

10 + 0

3.3

10 + 2

10 + 0

10 + 0

3.4

10 + 2

10 + 1

10 + 1

3.5

10 + 3

10 + 1

10 + 2

3.6

10 + 4

10 + 2

10 + 3

3.7

10 + 4

10 + 3

10 + 3

3.8

10 + 5

10 + 3

10 + 4

3.9

10 + 6

10 + 4

10 + 5

4.0

10 + 6

10 + 5

10 + 5

4.1

11 + 0

10 + 5

10 + 6

4.2

11 + 1

10 + 6

11 + 0

4.3

11 + 1

11 + 0

11 + 0

4.4

11 + 2

11 + 0

11 + 1

4.5

11 + 3

11 + 1

11 + 2

4.6

11 + 3

11 + 1

11 + 2

4.7

11 + 4

11 + 2

11 + 3

4.8

11 + 5

11 + 3

11 + 4

4.9

11 + 5

11 + 3

11 + 4

5.0

11 + 6

11 + 4

11 + 5

5.1

12 + 0

11 + 4

11 + 5

5.2

12 + 0

11 + 5

11 + 6

5.3

12 + 1

11 + 5

12 + 0

5.4

12 + 1

11 + 6

12 + 0

5.5

12 + 2

11 + 6

12 + 1

5.6

12 + 3

12 + 0

12 + 2

5.7

12 + 3

12 + 1

12 + 2

5.8

12 + 4

12 + 1

12 + 3

5.9

12 + 4

12 + 2

12 + 3

6.0

12 + 5

12 + 2

12 + 4

6.1

12 + 6

12 + 3

12 + 5

6.2

12 + 6

12 + 3

12 + 5

6.3

13 + 0

12 + 4

12 + 6

6.4

13 + 0

12 + 4

12 + 6

6.5

13 + 1

12 + 5

13 + 0

6.6

13 + 2

12 + 5

13 + 0

(MacGregor SN, Tamura RK, Sabbagha RE et al: Underestimation of gestational age by conventional crown-rump length growth curves.Obstet Gynecol 70:344, 1987.Reprinted with permission of American College of Obstetricians and Gynecologists)

Variations in the measurement of CRL can be attributed to differences in fetal growth patterns. Such differences are related to factors similar to those that influence birth weight curves, including maternal age and parity, prepregnancy maternal weight, geographic location, and population characteristics.53,54,55 Indeed, the existence of subpopulations with altered CRL growth patterns has been suggested by previous reports.56,57 Technical factors can also lead to errors in CRL measurements. These include incorporation of the yolk sac or lower limbs in the CRL measurement, excessive curling or extension of the fetus, and tangential section of the trunk.17 Despite these potential sources of error, CRL measurement is an accurate and useful method of assessing gestational age in the first trimester.

Second- and Third-Trimester Assessment

BIPARIETAL DIAMETER.

The biparietal diameter (BPD) is one of the most commonly measured parameters in the fetus. Campbell was the first investigator to link fetal BPD to gestational age20; however, since this original report, numerous publications on this subject have appeared in the literature.20,21,22,23,24,25,26,27,28,58,59,60,61,62,63 The BPD may be rapidly and reproducibly measured by ultrasound examination from 12 weeks' gestation until the end of pregnancy. The BPD is imaged in the transaxial plane of the fetal head at a level depicting thalami in the midline, equidistant from the temporoparietal bones and usually the cavum septum pellucidum anteriorly (Fig. 3).58,59 Although several methods have been used to measure BPD, the most commonly accepted method is measurement from leading edge to leading edge (outer-to-inner) (see Fig. 3).

Fig. 3. Transaxial image of the fetal head for biparietal diameter and head circumference measurements. A. Ultrasound image with biparietal diameter measurement ( between the solid arrows, outer edge to inner edge) and fronto-occipital diameter measurement ( between the open arrows ). The head circumference may be calculated using these diameters or measured directly. B. Diagram of the transaxial ultrasound image of the fetal head at the level of the thalami ( large arrows ), midline falx ( curved arrow ), and cavum septi pellucidi ( open arrow ).

Gestational age assignment is based on the mean BPD; however, a single BPD encompasses a range of ages in which most fetuses of that size are most likely to fall (Table 4).23 The accuracy of fetal age assessment based on BPD is dependent on gestational age.22,23,27,28,51,58 Between 12 and 26 weeks' gestation, the BPD is accurate to within ±10 to 11 days. After 26 weeks' gestation, the accuracy of BPD measurement progressively decreases and is ±3 weeks near term. A number of factors may contribute to variation or inaccuracy in the BPD measurement. Biologic variation, for example, may occur because of differences in maternal age, parity, prepregnancy weight, geographic location, and specific population characteristics. Technical factors including interobserver error, different techniques of measurements, and single versus multiple measurements may likewise influence the accuracy of BPD in assessing gestational age.60,61,62 Although most dating curves show the same general relationship between BPD and gestational age, there are often significant differences in gestational age assignment for any particular BPD measurement. Furthermore, BPD measurement is most accurate in assessing gestational age when the head shape is appropriately ovoid. If the head is unusually rounded (brachycephalic) or unusually elongated (dolicocephalic), BPD measurements would overestimate or underestimate gestational age, respectively. To determine whether head shape is appropriate, Hadlock and co-workers64 compared the BPD and the frontooccipital diameter. The ratio of these diameters is called the cephalic index (CI), with a mean value of 0.78 and a normal range (±2 SD) of 0.70 to 0.86. In the fetus with an abnormal cephalic index (noted in <2% of fetuses prior to 26 weeks' gestation), dates may be estimated more accurately using other fetal parameters, such as head circumference.

TABLE 4. Biparietal Diameter Measurements Relative to Gestational Age

Menstrual

Menstrual

BPD (cm)

Age (weeks)

BPD (cm)

Age (weeks)

2.6

13.6

6.4

25

2.7

13.8

6.5

25.3

2.8

14

6.6

25.7

2.9

14.2

6.7

26

3.0

14.4

6.8

26.3

3.1

14.7

6.9

26.7

3.2

15

7.0

27

3.3

15.2

7.1

27.3

3.4

15.4

7.2

27.7

3.5

15.7

7.3

28

3.6

16

7.4

28.3

3.7

16.3

7.5

28.7

3.8

16.7

7.6

29

3.9

17

7.7

29.4

4.0

17.3

7.8

30

4.1

17.7

7.9

30.4

4.2

18

8.0

31

4.3

18.3

8.1

31.4

4.4

18.7

8.2

32

4.5

19

8.3

32.3

4.6

19.3

8.4

32.7

4.7

19.7

8.5

33

4.8

20

8.6

33.4

4.9

20.3

8.7

34

5.0

20.7

8.8

34.6

5.1

21

8.9

35.3

5.2

21.3

9.0

36

5.3

21.6

9.1

36.4

5.4

21.8

9.2

37.3

5.5

22

9.3

37.7

5.6

22.3

9.4

39

5.7

22.7

9.5

40

5.8

23

9.6

40.3

5.9

23.3

9.7

40.7

6.0

23.7

9.8

41

6.1

24

9.9

41.7

6.2

24.3

10.0

42.3

6.3

24.7

(Sabbagha RE, Hughey M: Standardization of sonar cephalometry and gestational age. Obstet Gynecol 52:402, 1978. Reprinted with permission of American College of Obstetricians and Gynecologists)

HEAD CIRCUMFERENCE.

The head circumference (HC) measurement may be used to estimate gestational age in a similar manner to BPD measurement (Table 5).30 Although tracing of the outer perimeter of the head (by trackball on the ultrasonic equipment or by digitizer) is the most reliable means of measuring HC, the following formula using biparietal and fronto-occipital diameters may be used to calculate HC with a maximum error of 6%:63,65

TABLE 5.Head Circumference Measurements Relative to Gestational Age

Head

Menstrual

Head

Menstrual

Circumference

Age

Circumference

Age

(cm)

(weeks)

(cm)

(weeks)

8.0

13.4

22.5

24.4

8.5

13.7

23.0

24.9

9.0

14.0

23.5

25.4

9.5

14.3

24.0

25.9

10.0

14.6

24.5

26.4

10.5

15.0

25.0

26.9

11.0

15.3

25.5

27.5

11.5

15.6

26.0

28.0

12.0

15.9

26.5

28.1

12.5

16.3

27.0

29.2

13.0

16.6

27.5

29.8

13.5

17.0

28.0

30.3

14.0

17.3

28.5

31.0

14.5

17.7

29.0

31.6

15.0

18.1

29.5

32.2

15.5

18.4

30.0

32.8

16.0

18.8

30.5

33.5

16.5

19.2

31.0

34.2

17.0

19.6

31.5

34.9

17.5

20.0

32.0

35.5

18.0

20.4

32.5

36.3

18.5

20.8

33.0

37.0

19.0

21.2

33.5

37.7

19.5

21.6

34.0

38.5

20.0

22.1

34.5

39.2

20.5

22.5

35.0

40.0

21.0

23.0

35.5

40.8

21.5

23.4

36.0

41.6

22.0

23.9

(Hadlock FP, Deter RL, Harrist RB, Park SK: Fetal head circumference: Relation to menstrual age.AJR 138:649, 1982.Reprinted with permission of Williams & Wilkins, Baltimore.)

The accuracy of gestational age estimation by HC measurement is comparable with that of BPD measurement.30 However, in fetuses with abnormal head shape, either brachycephaly or dolicocephaly, HC may be a more accurate predictor of fetal age than BPD.30,65

ABDOMINAL CIRCUMFERENCE.

Measurement of the fetal abdominal circumference (AC) is obtained in the transaxial view of the fetal abdomen. The AC is measured at the level of the fetal liver, using the umbilical portion of the left portal vein as a landmark (Fig. 4). The fetal stomach is at the same level, which is slightly caudad to the fetal heart and cephalad to the kidneys. The AC measurement is taken from the outermost aspects of the fetal soft tissues. Measurement of the AC is performed in the same manner as that of the HC, that is, by (1) tracing the outer perimeter of the AC by the trackball on the ultrasonic equipment or by digitizer or (2) the same equation as for HC using transverse and anteroposterior diameters of the fetal abdomen. The AC may be used to estimate gestational age (Table 6) but is less accurate than head measurements (BPD or HC).33 Similar to head measurements, the accuracy of AC in estimating gestational age is greatest in the second trimester, with decreasing accuracy near term. Biologic variation and technical factors may contribute to the inaccuracy of AC measurements in a manner similar to that previously described for bi-parietal diameters. Of particular note, the abdominal circumference is the growth parameter most commonly affected in pregnancies complicated by abnormal fetal growth patterns.33 A macrosomic fetus will have increased AC relative to gestational age, and an asymmetrically growth-retarded fetus will have diminished AC measurements. Variation in AC measurements in macrosomic and growth-retarded fetuses is due to differences in liver size and width of subcutaneous tissue in these two types of abnormal growth patterns. Thus, estimation of gestational age by AC will lead to inaccuracies in fetuses displaying either of these growth patterns. However, the HC/AC ratio may be useful as a predictor of head-to-abdomen symmetry or asymmetry in order to identify the type of abnormal growth (Table 7).66

TABLE 6. Abdominal Circumference Measurements Relative to Gestational Age

Abdominal

Menstrual

Abdominal

Menstrual

Circumference

Age

Circumference

Age

(cm)

(weeks)

(cm)

(weeks)

10.0

15.6

23.5

27.7

10.5

16.1

24.0

28.2

11.0

16.5

24.5

28.7

11.5

16.9

25.0

29.2

12.0

17.3

25.5

29.7

12.5

17.8

26.0

30.1

13.0

18.2

26.5

30.6

13.5

18.6

27.0

31.1

14.0

19.1

27.5

31.6

14.5

19.5

28.0

32.1

15.0

20.0

28.5

32.6

15.5

20.4

29.0

33.1

16.0

20.8

29.5

33.6

16.5

21.3

30.0

34.1

17.0

21.7

30.5

34.6

17.5

22.2

31.0

35.1

18.0

22.6

31.5

35.6

18.5

23.1

32.0

36.1

19.0

23.6

32.5

36.6

19.5

24.0

33.0

37.1

20.0

24.5

33.5

37.6

20.5

24.9

34.0

38.1

21.0

25.4

34.5

38.7

21.5

25.9

35.0

39.2

22.0

26.3

35.5

39.7

22.5

26.8

36.0

40.2

23.0

27.3

36.5

40.8

(Hadlock FP, Deter RL, Harrist RB, Park SK: Fetal abdominal circumference as a predictor of menstrual age. AJR 139:367, 1982. Reprinted with permission of Williams & Wilkins, Baltimore.)

TABLE 7. Head Circumference to Abdominal Circumference Ratios Relative to Gestational Age

Gestational Age

HC/AC Ratio

(weeks)

5th percentile

Mean

95th percentile

13–14

1.14

1.23

1.31

15–16

1.05

1.22

1.39

17–18

1.07

1.18

1.29

19–20

1.09

1.18

1.26

21–22

1.06

1.15

1.25

23–24

1.05

1.13

1.21

25–26

1.04

1.13

1.22

27–28

1.05

1.13

1.22

29–30

0.99

1.10

1.21

31–32

0.96

1.07

1.17

33–34

0.96

1.04

1.11

35–36

0.93

1.02

1.11

37–38

0.92

0.98

1.05

39–40

0.87

0.97

1.06

41–42

0.93

0.96

1.00

(Campbell S, Thoms A: Ultrasound measurement of the fetal head to abdomen circumference ratio in the assessment of growth retardation. Br J Obstet Gynaecol 84:165, 1977. Reprinted with permission of Blackwell Scientific Publications, Oxford, England.)

Fig. 4. Transaxial image of the upper fetal abdomen. A. Ultrasound image with anteroposterior ( solid arrows) and transverse ( open arrows) diameter measurements. The abdominal circumference may be calculated using these diameters or measured directly. B. Diagram of the transaxial ultrasound image of the fetal abdomen at the level of the abdominal circumference measurement with fetal spine ( curved arrow ), the umbilical portion of the left portal vein ( solid arrow ), and fetal stomach ( open arrow)

FEMUR LENGTH.

All the fetal long bones can be adequately examined and measured by ultrasound; however, the femur is the largest of the long bones, least moveable, and easiest to image. The femur may be adequately visualized from 14 weeks' gestation until delivery.38,39,40,67,68,69,70,71,72,73,74 It is measured along the long axis of the bone; a straight measurement of the osseous portion is taken from one end to the other, disregarding bone curvature (Fig. 5). The femoral neck and both proximal and distal epiphyseal cartilages are excluded from the measurement. Femur length (FL) measurements may be used to accurately predict gestational age between 14 weeks' gestation and term (Table 8).39 Most observers consider the accuracy of the FL and BPD measurements to be similar in the third trimester. Although there is controversy regarding the accuracy of the FL prior to 26 weeks' gestation,38,39 the accuracy of gestational age prediction based on FL is greatest in the second trimester and least near term.

TABLE 8. Femur Length Measurements Relative to Gestational Age

Femur

Menstrual

Femur

Menstrual

Length

Age

Length

Age

(cm)

(weeks)

(cm)

(weeks)

1.0

12.8

4.5

24.5

1.1

13.1

4.6

24.9

1.2

13.4

4.7

25.3

1.3

13.6

4.8

25.7

1.4

13.9

4.9

26.1

1.5

14.2

5.0

26.5

1.6

14.5

5.1

27.0

1.7

14.8

5.2

27.4

1.8

15.1

5.3

27.8

1.9

15.4

5.4

28.2

2.0

15.7

5.5

28.7

2.1

16.0

5.6

29.1

2.2

16.3

5.7

29.6

2.3

16.6

5.8

30.0

2.4

16.9

5.9

30.5

2.5

17.2

6.0

30.9

2.6

17.6

6.1

31.4

2.7

17.9

6.2

31.9

2.8

18.2

6.3

32.3

2.9

18.6

6.4

32.8

3.0

18.9

6.5

33.3

3.1

19.2

6.6

33.8

3.2

19.6

6.7

34.2

3.3

19.9

6.8

34.7

3.4

20.3

6.9

35.2

3.5

20.7

7.0

35.7

3.6

21.0

7.1

36.2

3.7

21.4

7.2

36.7

3.8

21.8

7.3

37.2

3.9

22.1

7.4

37.7

4.0

22.5

7.5

38.3

4.1

22.9

7.6

38.8

4.2

23.3

7.7

39.3

4.3

23.7

7.8

39.8

4.4

24.1

7.9

40.4

(Hadlock FP, Harrist RB, Deter RL, Park SK; Fetal femur length as a predictor of menstrual age. AJR 138:875, 1982. Reprinted with permission of Williams & Wilkins, Baltimore.)

Fig. 5. Linear array image of the fetal femur. The femur length is measured between the arrows.

Biologic variation may lead to inaccuracies of FL measurements in a manner similar to that of the other fetal growth parameters. In addition, several technical factors are potential sources of error in the measurement of the femur.67,70,72 Sector ultrasound imaging may lead to overestimation of FL, particularly when the femur is in the far field or lateral margins of the image. Linear-array ultrasound imaging provides more accurate measurements of FL. In addition, FL measurements obtained in the axial plane (parallel to the ultrasonic beam) have less mean absolute error than those obtained in the lateral plane, perpendicular to the ultrasonic beam (1.7 mm vs. 3.7 mm, respectively).74 Tangential section of the femur, failing to visualize the entire length of the shaft, leads to underestimation of FL and, therefore, of gestational age. Artifactual bowing of the femur may also occur on ultrasound imaging and lead to a shortened FL measurement. The distal femoral epiphysis becomes echogenic in the third trimester and is separated from the distal end of the diaphysis, the osseous portion of the shaft. Inclusion of the distal epiphysis will falsely overestimate FL.67,68

Gestational age assessment by FL is particularly useful when head measurement is difficult to obtain due to fetal position. The femur length may also be compared with the biparietal diameter (FL/BPD) as an age-independent ratio.73 The FL/BPD ratio (normal values

A single parameter (CRL, BPD, HC, AC, or FL) may be used to assess gestational age. The accuracy of a single parameter is dependent on the gestational age at the time of ultrasound examination (Table 9). Several methods have been employed to improve the accuracy of gestational age assessment compared with the use of a single parameter. Two of these methods, growth-adjusted sonographic age79 and averaging multiple parameters80,81 are discussed. Several principles are important to remember when assessing gestational age by ultrasound:

TABLE 9.Ultrasound Predictors of Gestational Age

Estimated Range for

Parameter*

95% of Cases

Gestational sac mean diameter

± week

Crown-rump length

± 5–7 days

BPD, 12–26 weeks

± 10–11 days

HC, 12–26 weeks

± 10–14 days

AC, 12–26 weeks

± 10–14 days

FL, 12–26 weeks

± 10–20 days

BPD, 27–42 weeks

± 2–3 weeks

HC, 27–42 weeks

± 2–3 weeks

AC, 27–42 weeks

± 2–3 weeks

FL, 27–42 weeks

± 2–3 weeks


* See text for abbreviations.

  1. When menstrual dates fall within the confidence limits of the ultrasound assessment, the role of ultrasound is to confirm menstrual dates.
  2. When menstrual dates fall outside the confidence limits of ultrasound assessment, assignment of dates should be based on ultrasound assessment of gestational age.
  3. When menstrual dates are unknown, assignment of dates should be based on ultrasound assessment of gestational age.

Growth-Adjusted Sonographic Age

Gestational age estimation using a single biparietal diameter is accurate within a margin of ±10 to 11 days in the second trimester. Gestational age can be more accurately predicted by obtaining paired BPD measurements (the first from 20 to 26 weeks' gestation and the second from 31 to 33 weeks' gestation) and assigning gestational age by a method developed by Sabbagha and co-workers79 known as growth-adjusted sonographic age (GASA).

In approximately 90% of fetuses, BPD growth from 20 to 33 weeks' gestation tends to progress within narrow percentile ranks (Table 10).21,25 BPD growth patterns can be subdivided into three types: large (

90th percentile); average (10th to 90th percentile); and small (
10th percentile). Paired BPD measurements obtained at different gestational ages allows categorization of the specific cephalic growth pattern. The first measurement should be obtained between 20 and 26 weeks' gestation, and the second measurement should be obtained between 30 and 33 weeks' gestation. The first BPD measurement will not distinguish the fetus with large, average, or small BPD growth, and, therefore, the fetus is assigned a mean gestational age based on an assumed average BPD growth pattern. The second BPD measurement identifies the specific type of growth pattern. For example, in the fetus with average growth the second BPD measurement will fall between the 10th and 90th percentiles, confirming the gestational age assignment from the first BPD measurement. In contrast, BPD growth in the small-for-gestational age fetus will follow a slow growth pattern and the second BPD measurement will be less than or equal to the 10th percentile for the gestational age assigned by the first BPD. Since the first BPD measurement failed to recognize the small growth pattern and, therefore, underestimated gestational age, the second measurement allows the gestational age assessment to be adjusted based on the BPD growth pattern. Such a fetus with a slowed growth pattern would have the gestational age advanced by 1 week at the time of the second BPD measurement. Similarly, dates in the large-for-gestational age fetus may be adjusted by GASA at the time of the second BPD measurement, decreasing gestational age assignment by 1 week if the BPD measurement is greater than or equal to the 90th percentile (Fig. 6). Use of GASA has been reported to increase the accuracy of gestational age estimation by BPD measurement to within ±3 to 5 days.79

TABLE 10. Assignment of Growth-Adjusted Sonographic Age (GASA)

First Sonar*

(BPD vs Fetal Age Percentile Range)

Second Sonar† (BPD Percentile Range)

Large Fetus

Average Fetus

vs Small

(age accepted

Fetal Age

Average BPD

Large BPD

Small BPD

BPD

Fetus (wk)

temporarily)

(wk)

>10 <90

90

10

2.8

±1

14

3.2

±1

15

29

7.0–8.1

8.2

6.9

3.5

±1

16-

3.6

±1.6

16

30

7.3–8.4

8.5

7.2

3.7

±1.6

16+

3.8

±1.6

17-

30+

7.4–8.5

8.6

7.3

3.9

±1.6

17

4.0

±1.6

17+

31-

7.4–8.5

8.6

7.3

4.1

±1.6

18-

4.2

±1.6

18

31

7.5–8.6

8.7

7.4

4.3

±1.6

18+

4.4

±1.6

19-

31+

7.6–8.7

8.8

7.5

4.5

±1.6

19

4.6

±1.6

19+

32-

7.6–8.7

8.8

7.5

4.7

±1.6

20-

4.8

±1.6

20

32

7.7–8.8

8.9

7.6

4.9

±1.6

20+

5.0

±1.6

21-

32+

7.8–8.9

9.0

7.7

5.1

±1.6

21

5.2

±1.6

21+

33-

7.8–8.9

9.0

7.7

5.3

±1.6

22-

5.4

±1.6

22-

33

7.9–9.0

9.1

7.8

5.5

±1.6

22

5.6

±1.6

22+

33+

8.0–9.0

9.1

7.8

5.7

±1.6

23-

5.8

±1.6

23

34-

8.0–9.0

9.1

7.9

5.9

±1.6

23+

6.0

±1.6

24-

34

8.1–9.1

9.2

8.0

6.1

±1.6

24

6.2

±1.6

24+

35

8.4–9.4

9.5

8.3

6.3

±1.6

25-

6.4

±1.6

25

6.5

±1.6

25+

6.6

±1.6

26-

6.7

±1.6

26


BPD = biparietal diameter; + = plus 1 to 3 days; - = minus 1 to 3 days.
* First sonar is done prior to 26 weeks because of small variation in fetal age of ±11 days.
† Second sonar: (1) Must be done between 30 to 33 weeks because of maximal variation in fetal BPD size in this interval and prior to onset of IURG in most cases.(2) Must be done at least 6 weeks after first BPD
(Adapted from Sabbagha RE, Hughey M, Depp R: Growth adjustment sonographic age [GASA]: A simplified method.Obstet Gynecol 51:383, 1978: and Evans CB, Motew MN, Sabbagha RE: Growth adjusted sonographic age [GASA]: Expansion of the margins delineating the fetus with average BPDs to the 10th and 90th percentiles.Obstet Gynecol (in press).Reprinted with permission of American College of Obstetricians and Gynecologists.

The method of GASA has not been used when the first BPD measurement is obtained prior to 20 weeks' gestation; therefore, it is best to confine the use of GASA to pregnancies in which serial ultrasound studies are contemplated and the first measurement is obtained between 20 and 26 weeks' gestation. Smazal and associates51 evaluated the method of GASA and suggested that the accuracy was indeed ±5 days. However, in this report, the accuracy of a single BPD was also approximately ±5 days.

Multiple Fetal Growth Parameters

Hadlock and co-workers80,81 combined several measurements in an effort to increase the accuracy of gestational age assessment. The rationale for employing multiple parameters for fetal dating is that when two or more parameters predict the same end point, the probability of correctly predicting that end point is increased. The BPD, HC, AC, and FL measurements were obtained and the mean gestational ages of combinations of these parameters were averaged to obtain a mean gestational age. The use of multiple parameters improved the accuracy of gestational age assessment compared with any single parameter (Table 11).80 If the gestational age estimates derived from all of the parameters are similar, assignment of gestational age from the average of all the parameters will improve accuracy. However, if gestational age estimates of the various parameters are quite different, averaging multiple parameters will decrease the accuracy of the best predictor(s). Averaging of fetal growth parameters should be avoided when certain conditions are suspected, such as fetal macrosomia, intrauterine growth retardation (both symmetric and asymmetric), and congenital anomalies (skeletal dysplasias, hydrocephalus, and others).

TABLE 11. Accuracy of Gestational Age Assessment by Multiple Fetal Growth Parameter

Subgroup Variability (±2 SD) in Weeks

Fetal

12–18 Weeks

18–24 Weeks

24–30 Weeks

30–36 Weeks

36–42 Weeks

Parameters

(N = 43)

(N = 69)

(N = 76)

(N = 95)

(N = 78)

BPD

±1.19

±1.73

±2.18

±3.08

±3.20

HC

±1.19

±1.48

±2.06

±2.98

±2.70

AC

±1.66

±2.06

±2.18

±2.96

±3.04

FL

±1.38

±1.80

±2.08

±2.96

±3.12

BPD, AC

±1.26

±1.68

±1.92

±2.60

±2.88

BPD, AC

±1.08

±1.49

±1.99

±2.86

±2.64

BPD, FL

±1.12

±1.46

±1.84

±2.60

±2.62

HC, AC

±1.20

±1.52

±1.98

±2.68

±2.52

HC, FL

±1.08

±1.34

±1.86

±2.52

±2.28

AC, FL

±1.32

±1.64

±1.88

±2.66

±2.60

BPD, AC, FL

±1.20

±1.52

±1.82

±2.50

±2.52

BPD, HC, FL

±1.04

±1.35

±1.81

±2.52

±2.34

HC, AC, FL

±1.14

±1.46

±1.86

±2.52

±2.34

HC, AC, BPD

±1.21

±1.58

±1.94

±2.60

±2.52

BPD, HC, AC, FL

±1.08

±1.40

±1.80

±2.44

±2.30

(Hadlock FP, Deter RL, Harrist RB, Park SK: Estimating fetal age: Computer-assisted analysis of multiple fetal growth parameters. Radiology 152:497, 1984. Reprinted with permission of Radiological Society of North America, Oak Brook, IL.)

Multiple Gestations

The detection of multiple gestations is important since multiple gestations are at greater risk for many complications, particularly fetal growth retardation. Fetal biometric data are available for twin gestations81,82,83,84,85; however, triplet and quadruplet pregnancies have not been adequately studied owing to their infrequent occurrence.

In general, ultrasound-derived fetal dating tables obtained for singleton pregnancies can be used accurately for twin pregnancies until approximately 30 weeks' gestation.82,83,84,85,86 During the last 10 weeks of pregnancy there is a decrease in the growth rate for twin fetuses compared with singleton fetuses. Grumbach and co-workers86 have suggested that the femur continues to grow normally throughout pregnancy in twin gestations, while the head (BPD and HC) and abdominal (AC) growth rates decrease in the last 10 weeks of pregnancy. Although further studies are required to confirm these findings, this study suggests that FL measurement may be a more reliable parameter to use for gestational age assessment in twin gestations during the third trimester. Gestational age estimations in twin pregnancies prior to 30 weeks' gestation should be performed in a similar manner to that for singleton pregnancies.

How can an ultrasound tell the age of a fetus?

on Ultrasound Findings Ultrasound biometric measurements determine gestational age based on the assumption that the size of the embryo or fetus is consistent with its age. Biological variation in size is less during the first trimester than in the third trimester.

How accurate is age of fetus?

Current clinical methods of estimating fetal gestational age are often inaccurate. For example, between 20 and 30 weeks of gestation, the width of the 95% prediction interval around the actual gestational age is estimated to be 18–36 days, even when the best ultrasound estimates are used.

Toplist

Latest post

TAGs